Our Products

Vinyl Chloride Insulated low-voltage cables for automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

 AV, AVF, & HEB

PVC

-40°C to +80°C

JASO D 611:2014

Thin Wall Vinyl Chloride Insulated low-voltage cables for automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

 AVS, AVSF

PVC

-40°C to +80°C

JASO D 611:2014

Vinyl Chloride Insulated low-voltage cables for automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

 AVSS, AVSSF

PVC

-40°C to +80°C

JASO D 611:2014

Very Thin Wall PVC Insulated Heat Resistant Low-Voltage Cables for Automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

AVSSHF

PVC

-40°C to +100°C

JASO D 611:2014

Cross-linked vinyl chloride insulated heat resistant low-voltage cables for automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

 AVX

Cross-Linked PVC

-40°C to +80°C

JASO D 611:2014

Very thin wall cross-linked PVC insulated heat resistant  low-voltage cables for automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

 AVSSX

PVC

-40°C to +80°C

JASO D 611:2014

Very thin wall cross-linked polythene insulated heat resistant  low-voltage cables for automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

AESSX

Cross-Linked Polyethylene

-40°C to +120°C

JASO D 611:2014

Thin Wall Vinyl Chloride Insulated low-voltage cables for automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

CAVS, ACCAVS

PVC

-40°C to +80°C

JASO D 611:2014

Ultra-Thin Wall Vinyl Chloride Insulated Low-Voltage Cables for Automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

CIVUS, ACCIVUS

PVC

-40°C to +85°C

JASO D 611:2014

Very Thin Wall Vinyl Chloride Insulated Heat Resistant Low-Voltage Cables for Automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

IVSSHF

PVC

-40°C to +100°C

JASO D 611:2014

Vinyl Chloride Insulated low-voltage cables for automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

EB

PVC

-40°C to +80°C

JASO D 611:2014

CABLE LOW TENSION, HALOGEN FREE XLPE, ULTRA THIN INSULATION

Cable Type 

Insulation Material

Temperature Range

Reference Standard

PSA (T3)

T3 XLPE

-40°C to +125°C

B25 1110

Very Thin Wall Vinyl Chloride Insulated Heat Resistant Low-Voltage Cables for Automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

PSA (T4)

T4 XLPE

-40°C to +150°C

B25 1110

600 V ac / 1000 V dc 

Cable Type 

Insulation Material

Temperature Range

Reference Standard

HV CABLE (T3)

 XLPE

-40°C to +125°C

ES-AU5T-1A348-AA

600 V ac / 1000 V dc 

1000 V ac / 1500 V dc

Cable Type 

Insulation Material

Temperature Range

Reference Standard

HV CABLE (T4)

XLPE

-40°C to +150°C

ES-AU5T-1A348-AA

AVSS CORE, COPER TAPE SHIELDED, PVC SHEATHED LOW TENSION AUTOMOTIVE CABLE (THIN SHEATH TYPE)

Cable Type 

Insulation Material

Temperature Range

Reference Standard

SHIELED CABLE

PVC

-40°C to +80°C

YPES-11-01-180

CABLE, LV, MULTICONDUCTOR, COPPER, PVC INSULATION, PVC JACKET

Cable Type 

Insulation Material

Temperature Range

Reference Standard

MULTI CORE CABLE

 PVC

-40°C to +100°C

ISO 6722-1:2011

Dimensions and requirements for 600 V a.c. or 900 V d.c. and 1000 V a.c. or 1500 V d.c. round, sheathed, screened or unscreened multi or single core copper conductor cables

Cable Type 

Insulation Material

Temperature Range

Reference Standard

SHEATHED CABLE

XLPE

-40°C to +125°C

ES-AU5T-1A348-AA

Part -1 Dimensions, test methods and requirements for 60 V or 600 V single core copper conductor cables

Cable Type 

Insulation Material

Temperature Range

Reference Standard

PSA (T4)

T4 XLPE

-40°C to +150°C

ISO 6722-1:2011,
ES-AU5T-1A348-AA,
MS.90034 , ES91110-05

Part -1 Dimensions, test methods and requirements for 60 V or 600 V single core copper conductor cables

Cable Type 

Insulation Material

Temperature Range

Reference Standard

T3 Cable

PVC / PP / T3 XLPE

-40°C to +125°C

ISO 6722-1:2011,ES-AU5T-1A348-AA,
MS.90034 , ES91110-05

Part -1 Dimensions, test methods and requirements for 60 V or 600 V single core copper conductor cables

Cable Type 

Insulation Material

Temperature Range

Reference Standard

T4 Cable

 XLPE

-40°C to +125°C

ISO 6722-1:2011,ES-AU5T-1A348-AA,
MS.90034 , ES91110-05

Ultra-Thin Wall Vinyl Chloride Insulated Low-Voltage Cables for Automobiles

Cable Type 

Insulation Material

Temperature Range

Reference Standard

CIVUS, ACCIVUS

PVC

-40°C to +100°C

YPES-11-01-254

Dimensions and requirements for 600 V a.c. or 900 V d.c. and 1000 V a.c. or 1500 V d.c. round, sheathed, screened or unscreened multi or single core copper conductor cables

Cable Type 

Insulation Material

Temperature Range

Reference Standard

ANTI CAPILLARY CABLE

XLPO

-40°C to +150°C

ES-AU5T-1A348-AA

Dimensions and requirements for 600 V a.c. or 900 V d.c. and 1000 V a.c. or 1500 V d.c. round, sheathed, screened or unscreened multi or single core copper conductor cables

Cable Type 

Insulation Material

Temperature Range

Reference Standard

SILICONE CABLE

 FEP or SiR, or XLFE

-40°C to +200°C

ES-AU5T-1A348-AA